Features
・Clamp-style couplings,available in a wide range combination of diameters:φ6 to φ14. ・Polyimide plate-type is particularly strong against misalignment,with good heat resistance and high electrical insulation. |
Configuration and materials
CUHL:Double plate
CUHS:Single plate |
|
Dimensions
Item No. | Standard hole diameters ød1,ød2 H8 | Plate materials | |||||||
---|---|---|---|---|---|---|---|---|---|
Double | CUHLP |
|
Polyimide (0.9t) | ||||||
CUHLC |
Carbon FRP (0.8t) | ||||||||
Single | CUHSP |
Polyimide (0.9t) | |||||||
CUHSC | Carbon FRP (0.8t) |
Specifications
Item No. | Allowable torque (N⋅m) | Maximum rotating speed (rpm) | Torsional rigidity (N⋅m/rad) |
Allowable parallel misalignment |
Radial rigidity (Shearing rigidity) (N/mm) | Allowable angular misalignment (°) |
Bending rigidity (N・m/rad) |
---|---|---|---|---|---|---|---|
CUHLP | 4 |
6,000 |
800 |
0.6 |
70 |
6 |
2 |
CUHLC | 7 | 8,000 |
1,500 |
0.3 |
150 |
3 |
5.2 |
CUHSP | 4 | 6,000 | 1,300 | 0.15 | 1,600 | 3 | 3.5 |
CUHSC | 7 | 8,000 |
2,400 |
0.07 |
2,300 |
1.5 |
7 |
Item No. |
Allowable end play (mm) |
Axial rigidity (N/mm) |
Allowable ambient temperrature |
Electrical insulation |
Moment of inertia (kg・m2) |
Fastening torque of clamp bolt (N・m) |
Mass (g) |
---|---|---|---|---|---|---|---|
CUHLP | 0.9 | 0.7 | -40~200 | High | 4.0x10-8 |
2.4 (φD≦8) 2.2 (φD=10) 2 (φD≧12) |
60 |
CUHLC | 0.4 | 1.1 | -25~85 | None | |||
CUHSP | 0.5 | 1.2 |
-40~200 |
High | 3.0x10-8 | 40 | |
CUHSC | 0.25 | 2.1 | -25~85 | None |
・Please conform to the clamp bolt fastening torque values listed in the above table.