Model | Dimensions(mm) | Specifications |
■Two-wire-system
|
|
Stroke |
1mm |
Operating force |
H : 4.5N |
J : 0.35N |
Movement until
the operation[PT]
|
0.2~0.5mm |
Hysteresis movement[MD] |
0.1mm or less |
Repeat accuracy |
±0.01mm |
Cable specifications |
STMB10VA-□:φ2.8 2wire, Gray 1m |
STMB10VB-□:φ2.8 2wire, Black 1m |
Case,Nut,Ball material |
SUS303 |
Mounting |
M10 nut tightening torque 12N・m |
Mounting hole processing deimensions |
φ100+0.5
|
Protective structure |
IP65 |
Curcuit diagram |
CNC-19 |
・Be sure to connect to the load before use. ・Cable extension are possible.
|
■Three-wire-system
|
■Examples of use
|
Stroke |
1mm |
Operating force |
H : 4.5N |
J : 0.35N |
Movement until
the operation[PT]
|
0.3~0.6mm |
Hysteresis movement[MD] |
0.1mm or less |
Repeat accuracy |
±0.01mm |
Cable specifications |
STMB10A-□:φ2.8 3wire, Gray 1m
|
STMB10B-□:φ2.8 3wire, Black 1m
|
Case,Nut,Ball material |
SUS303 |
Mounting |
M10 nut tightening torque 12N・m |
Mounting hole processing deimensions |
φ100+0.5
|
Indicator light |
STMB10○-□ : Without indicator light |
STMB10○-□-LED :
Approximately 100mm from the main unit
|
Protective structure |
IP65 |
Curcuit diagram |
STMB10○-□:CNC-3 |
STMB10○-□-LED:CNC-18 |
・By using cable options, conversion of output specifications, current amplification, and cable extension are possible.
|
|
|
Stroke |
1mm |
Operating force |
H : 7N |
J : 0.5N |
Movement until
the operation[PT]
|
0.3~0.6mm |
Hysteresis movement[MD] |
0.1mm or less |
Repeat accuracy |
±0.01mm |
Cable specifications |
STFB12A-□:φ2.8 3wire, Gray 1m |
STFB12B-□:φ2.8 3wire, Black 1m |
Case material |
SUS303 |
Ball material |
SUS |
Indicator light |
STFB12○-□ : Without indicator light |
STFB12○-□-LED :
Approximately 100mm from the main unit
|
Protective structure |
IP65 |
Curcuit diagram |
Without LED : CNC-3 |
With LED : CNC-18 |
・By using cable options, conversion of output specifications, current amplification, and cable extension are possible.
|