Touch switches

ModelDimensions(mm)Specifications

STM6

stm6 hinban 22

stm6 zu 22

Stroke 1.2mm
Operating force 0.3N

Movement until

the operation[PT]

0.2~0.5mm
Hysteresis movement[MD] 0.1mm or less
Repeat accuracy ±0.002mm
Cable specifications STM6 / STM6-LED:φ2.8 3wire, Gray 1m
STM6(B)/ STM6(B)-LED:φ2.8 3wire, Black 1m
Case,Nut,Shaft material SUS
Mounting M6 nut tightening torque 2N・m or less
Mounting hole
processing dimensions
φ6 0+0.5
Indicator light STM6/STM6 (B) : Without indicator light

STM6-LED/STM6(B)-LED :

Approximately 100mm from the main unit

Protective structure IP67
Curcuit diagram STM6 / STM6(B):CNC-3
STM6-LED / STM6(B)-LED: CNC-18

・Do not apply a force of 30N or more to the contact part.
・By using cable options, conversion of output specifications, current amplification, and cable extension are possible.

STM8

stm8 hinban 22

stm8 zu 22

 

 

STM8 en seal

Stroke 1.5mm
Operating force 0.4N

Movement until

the operation[PT]

0.2~0.5mm
Hysteresis movement[MD] 0.1mm or less
Repeat accuracy ±0.001mm
Cable specifications

STM8 / STM8-LED:φ2.8 3wire, Gray 1m

STM8(B)/ STM8(B)-LED:φ2.8 3wire, Black 1m

Case,Nut,Shaft material SUS303
Mounting M8 nut tightening torque 5N・m or less
Mounting hole
processing dimensions
φ8 0+0.5
Indicator light STM8/STM8(B) : Without indicator light

STM8-LED/STM8(B)-LED :

Approximately 100mm from the main unit

Protective structure IP67
Curcuit diagram STM8 / STM8(B):
CNC-3
STM8-LED / STM8(B)-LED:
CNC-18

・Do not apply a force of 30N or more to the contact part.
・By using cable options, conversion of output specifications, current amplification, and cable extension are possible.

STM8L

stm8l hinban 22

stm8l zu 22

Stroke 3mm
Operating force 0.7N

Movement until

the operation[PT]

0.2~0.5mm
Hysteresis movement[MD] 0.1mm or less
Repeat accuracy ±0.001mm
Cable specifications STM8L / STM8L-LED:φ2.8 3wire, Gray 1m
STM8L(B)/ STM8L(B)-LED:
φ2.8 3wire, Black 1m
Case,Nut,Shaft material SUS303
Mounting M8 nut tightening torque 5N・m or less
Mounting hole
processing dimensions
φ8 0+0.5
Indicator light STM8L/STM8L(B) : Without indicator light

STM8L-LED/STM8L(B)-LED :

Approximately 100mm from the main unit

Protective structure IP67
Curcuit diagram STM8L / STM8L(B):
CNC-3
STM8L-LED / STM8L(B)-LED:
CNC-18

・Do not apply a force of 30N or more to the contact part.
・By using cable options, conversion of output specifications, current amplification, and cable extension are possible.